Catalogue Highlights

Featured Low-Voltage Equipment for Bago Wholesalers

Direct factory access to top-tier DIN-rail automatic transfer switches, smart breakers, manual isolators, and power distribution cabinets optimized for Myanmar’s electrical conditions.

TOMZN 4P 3 Phase 4 Wire Din Rail ATS

TOMZN 4P 3 Phase 4 Wire Din Rail ATS PV and Inverter Dual Power Switches 63A 100A 125A

View Product
TOMZN WIFI Smart Circuit Breaker 2P 230V

TOMZN WIFI Smart Circuit Breaker 2P 230V AC 1-100A Overload Protection Smartlife

View Product
TOMZN SmartLife WiFi Smart ATS 2P4P 63A

TOMZN SmartLife WiFi Smart ATS 2P4P 63A Dual Power Auto Transfer Switch AC220V 230V

View Product
TOMZN TUYA SmartLife WIFI Smart ATS Dual Power

TOMZN TUYA SmartLife WIFI Smart ATS Dual Power Selector Switch 2P 230V 63A 100A 125A

View Product
TOMZN 125A 2P Plus 2P DC MTS

TOMZN 125A 2P Plus 2P DC MTS Dual Power Manual Transfer Switch Breaker for PV System

View Product
TOMZN 3 Phase Din Rail ATS Dual Power Switch

TOMZN 3 Phase Din Rail ATS Dual Power Automatic Transfer Switch 4P 63A 100A 125A

View Product
TOMZN TUYA SmartLife ATS 4P AC230V 63A

TOMZN TUYA SmartLife ATS 4P AC230V 63A 100A 125A Automatic Transfer Switch TOQ7S

View Product
TOMZN Din Rail Flame-retardant Distribution Box

TOMZN Din Rail Flame-retardant Distribution Box / Cabinet Enclosure

View Product

Engineering Whitepaper: Class II / Type 2 Surge Protection Technology

Low-voltage power distribution networks across Southeast Asia, particularly in fast-growing regions like Bago (Myanmar), encounter recurring electrical disturbances. Transient overvoltages caused by atmospheric lightning discharges, inductive load switching, and power grid instability represent the single leading cause of premature failure in industrial drives, commercial HVAC units, and residential solar inverters. A Type 2 Surge Protective Device (SPD), also classified as Class II under IEC 61643-11 / EN 61643-11 standards, serves as the primary defense mechanism installed within main and sub-distribution panels.

Core Technical Function of Class II / Type 2 SPDs

Unlike Type 1 SPDs designed to handle direct lightning currents with an 10/350 µs waveform, Type 2 SPDs are engineered to suppress indirect lightning surges and induced switching transients characterized by an 8/20 µs current waveform. Positioned downstream from the service entrance (or combined with Type 1+2 units at the main switchboard), a Type 2 surge protector diverts excess surge currents harmlessly to earth while clamping residual transient voltage ($U_p$) below the dielectric withstand capability of protected terminal electronics.

Metal Oxide Varistor (MOV) Matrix

Our Type 2 SPDs utilize high-energy Zinc Oxide ($\text{ZnO}$) varistors sourced from top-tier raw material suppliers. When voltage spikes exceed the Maximum Continuous Operating Voltage ($U_c$), MOV resistance collapses from megohms to milliohms in under 25 nanoseconds, clamping the surge instantly.

Thermal Disconnector & Status Flag

Continuous grid overvoltages can drive varistors into thermal runaway. Our integrated internal disconnector mechanically isolates the MOV from the mains before thermal destruction occurs, triggering a visual status indicator (Green = Normal, Red = Replace).

Plug-in Modular Design

Designed for rapid maintenance on busy industrial sites, the DIN-rail base remains wired while individual cartridge modules can be hot-swapped without de-energizing the entire panel board, minimizing operational downtime.

Factory-Direct Type 2 Surge Protector Product Portfolio

Zhejiang DVS Electric Co., Ltd. manufactures a full spectrum of AC and DC Type 2 surge protectors designed specifically for electrical distributors, panel builders, and project contractors serving the Bago region.

AC Distribution

Single-Phase AC Type 2 SPD

Configuration: 1P+N, 2P
Nominal Voltage ($U_n$): 230V AC (50/60Hz)
Max Operating Voltage ($U_c$): 275V / 385V / 440V
Discharge Rating ($I_n / I_{max}$): 20kA / 40kA (8/20µs)
Voltage Protection Level ($U_p$): ≤ 1.5 kV
Ideal for residential distribution boxes, light commercial boards, and single-phase motor drives across Bago township.

Request Datasheet
Industrial AC

Three-Phase AC Type 2 SPD

Configuration: 3P+N (TT / TN-S Grid Systems)
Nominal Voltage ($U_n$): 400V AC 3-Phase
Max Operating Voltage ($U_c$): 385V / 440V AC
Discharge Rating ($I_n / I_{max}$): 20kA / 40kA & 30kA / 60kA
Auxiliary Contact: Remote status signaling optional
Essential for industrial workshops, textile factories, and rice mills in the Bago industrial zone.

Request Bulk Quote
Solar Photovoltaic

DC PV Type 2 Surge Protector

Configuration: 2P (Y-PV / Direct), 3P
System Voltage ($U_{cpv}$): 500V, 800V, 1000V, 1200V DC
Discharge Rating ($I_n / I_{max}$): 20kA / 40kA
Compliance: EN 50539-11 / IEC 61643-31
Engineered specifically for solar PV string combiner boxes and central/string inverters in agricultural and off-grid applications.

PV Product Catalog
Telecom & Data

Signal & Data Line SPD

Application: RS485, Ethernet, CCTV, Telecom
Operating Voltage ($U_c$): 5V, 12V, 24V, 48V DC
Bandwidth: High-frequency low loss
Connector Types: Screw Terminal, RJ45
Protects sensitive telemetry devices, remote terminal units (RTUs), and smart meters from indirect lightning surges.

Inquire Custom OEM

Localized Application Scenarios Across Bago, Myanmar

The geographic and infrastructural profile of Bago Region demands tailored surge protection strategies. Below are the prominent real-world deployment scenarios where our Type 2 SPDs deliver maximum ROI and grid resilience.

1. Bago Industrial Zone & Manufacturing Hubs

Factories along the Yangon–Bago industrial corridor rely heavily on automated looms, rice processing lines, and cold storage units. Power distribution panels in these environments experience intense switching surges from heavy inductive loads and frequent grid transfers. Installing our 3P+N Type 2 SPDs (385V/440V Uc, 40kA Imax) at sub-distribution boards prevents PLC lockups, VFD insulation breakdown, and costly machine downtime.

2. Agricultural Solar Water Pumping & Off-Grid PV

Throughout rural Bago, off-grid photovoltaic arrays drive agricultural water pumps and community mini-grids. Exposed rooftop and ground-mounted solar panels act as prime targets for induced atmospheric lightning transients during monsoon months. Our DC 1000V Type 2 SPDs installed inside PV combiner boxes safeguard solar charge controllers, battery storage units, and pumping inverters.

3. Telecom Towers & Remote Power Enclosures

Cellular base stations situated on elevated terrain across Bago experience intense thunderstorm activity. Outdoor cabinet power supplies and rectifiers require robust surge immunity. DVS Electric supplies compact DIN-rail Type 2 SPDs with integrated dry-contact microswitches, allowing telecom operators to monitor surge protector health remotely via centralized telemetry networks.

Bago Grid Dynamics & Surge Protection Trends

Understanding the local electrical ecosystem is crucial for selecting appropriate SPD parameters. Electrical contractors and importers in Bago face specific challenges driven by climate and grid infrastructure evolution.

High Keraunic Level & Tropical Monsoons

The Bago Region records high keraunic activity, averaging 60 to 90 thunderstorm days annually, concentrated heavily between May and October. Cloud-to-ground lightning strikes induce electromagnetic pulses (LEMP) into overhead distribution cables. Unprotected service panels experience voltage transients reaching several kilovolts, destroying un-suppressed electronics within milliseconds.

Grid Fluctuations & Hybrid Inverter Transition

Due to scheduled load shedding and voltage instabilities across local 230V/400V supply lines, businesses in Bago rely heavily on dual-power automatic transfer switches (ATS), diesel generators, and solar hybrid inverters. Rapid switching between grid power and backup sources generates significant switching surge transients. Choosing an SPD with elevated $U_c$ ratings (e.g., 385V or 440V AC) prevents premature varistor thermal aging caused by temporary overvoltages (TOV).

< 25 ns
Ultra-Fast MOV Response Time
40 kA
Standard Max Discharge Current ($I_{max}$)
100%
Factory Tested Under High-Impulse Lab
IEC 61643
International Compliance Guaranteed

Engineering Selection Matrix for Type 2 SPDs

Use the following technical selection guide to match DVS Type 2 Surge Protector specifications with your installation requirements in Bago.

Model Series Network / Voltage System Type In / Imax (8/20µs) Up (Clamping Voltage) Recommended Backup Protection
DVS-AC20-275 230V AC Single Phase TT / TN-S (1P+N) 20kA / 40kA ≤ 1.3 kV 32A C-Curve MCB / Fusible Disconnect
DVS-AC40-385 230V/400V 3-Phase TT / TN-S / TN-C (3P+N) 20kA / 40kA ≤ 1.8 kV 40A or 63A C-Curve MCB
DVS-AC60-440 400V Unstable Grid Heavy Industrial 3P+N 30kA / 60kA ≤ 2.0 kV 63A gL/gG Backup Fuse
DVS-PV600V 600V DC Solar String PV Array (2-Pole Y) 20kA / 40kA ≤ 2.5 kV Internal Thermal Isolation / DC Fuse
DVS-PV1000V 1000V DC Solar String Commercial PV (3-Pole) 20kA / 40kA ≤ 3.6 kV 1000V DC Photovoltaic Fuse Holder

Custom voltage parameters, custom packaging, and branded front-plate labeling available for Bago distributors upon request.

Why Partner with Zhejiang DVS Electric Co., Ltd.?

As a leading low-voltage electrical equipment manufacturer headquartered in Wenzhou—China's electrical capital—Zhejiang DVS Electric brings 24 years of manufacturing excellence to importers and contractors across Southeast Asia.

5,700 m² Modern Production Facility

Our dedicated manufacturing base houses automated SMT lines, MOV sorting stations, robotic housing assembly, and laser marking machinery. We maintain full control over quality and production speed.

In-House Impulse Testing Lab

Every batch of Type 2 surge protectors undergoes 100% calibration and routine verification. Our testing facility generates 8/20 µs current impulses up to 60kA to guarantee varistor clamping voltage accuracy.

OEM & ODM Customization for Bago

We provide full OEM branding, including private-label housing printing, custom retail packaging, bilingual English/Myanmar instruction manuals, and tailored technical specifications to help you build market dominance.

Contact Our OEM Export Division

Frequently Asked Questions from Bago Buyers & Engineers

Got questions about importing or installing Type 2 Surge Protectors? Here are technical answers from our engineering team.

What is the main difference between Type 1 and Type 2 Surge Protectors?
Type 1 SPDs are tested with a 10/350 µs waveform and designed to withstand direct lightning strikes; they are installed at the main electrical entrance. Type 2 SPDs are tested with an 8/20 µs waveform and protect against indirect lightning induced surges and grid switching transients. Type 2 units are installed at sub-distribution boards or directly upstream of critical loads.
Why is a 385V or 440V Uc rating recommended for 230V/400V grids in Bago?
Grids experiencing frequent load shedding and line imbalances often suffer from Temporary Overvoltages (TOV) where 230V phase voltage jumps above 275V for seconds or minutes. A Type 2 SPD rated at $U_c = 385\text{V}$ or $440\text{V}$ prevents the varistor from conducting during non-transient grid surges, preventing premature degradation while maintaining superior impulse protection.
What cable conductor cross-section should be used for Type 2 SPD connection?
According to IEC 60364-5-534 guidelines, connecting copper conductors for Type 2 SPDs should have a minimum cross-sectional area of $6\text{ mm}^2$ for phase and neutral lines, and at least $10\text{ mm}^2$ for the protective earth (PE) grounding wire. Connecting lead length should be kept under 0.5 meters to minimize inductive voltage drop ($V = L \cdot \frac{di}{dt}$).
Is backup overcurrent protection mandatory for Type 2 SPDs?
Yes. A dedicated Miniature Circuit Breaker (MCB) or fuse disconnector must be installed in series with the SPD branch. If the MOV reaches end-of-life under extreme continuous overvoltage, the dedicated backup MCB trips safely without disrupting power supply to the main facility branch.
What are your OEM delivery lead times and shipping terms for Myanmar / Bago?
For standard catalogue models, production takes 7 to 10 working days. Customized OEM orders (custom logo, special housing color, custom retail boxes) take approximately 15 to 20 days. We support FOB Ningbo/Shanghai, CIF Yangon Port, or door-to-door logistics arrangement with complete shipping documentation.
Do your Type 2 SPDs include dry-contact remote signal alarm outputs?
Yes, all our 1P+N, 3P+N, and DC PV Type 2 series can be ordered with optional remote signaling contacts (NO/NC). When the internal thermal trip disconnects a failed MOV module, the contact changes state to trigger an alarm on external PLCs, SCADA systems, or visual warning lights.

Accelerate Your Business in Bago with Factory-Direct Protection

Partner directly with Zhejiang DVS Electric Co., Ltd. Get wholesale factory pricing, certified quality, and dedicated engineering support for all your low-voltage protection projects.

Contact Us